More
Culligan Hi-Flo® 52 Softener Engineer’s Specification Page 23.2 DESIGN PARAMETERSNormal System Flow & Pressure Drop: gpm @ 15 PSIMa
Culligan Hi-Flo® 52 Softener Engineer’s Specification Page 3¨ (Steel vessel)4.1.4 Tank Finish – InteriorTank interior shall have near white sandblast
Culligan Hi-Flo® 52 Softener Engineer’s Specification Page 44.4 CONTROLSA fully integrated programmable micro-processor driven electronic controller s
Culligan Hi-Flo® 52 Softener Engineer’s Specification Page 5¨ (Meter Initiated, Alternating Twin Unit)An operator selected program of immediate volume
Culligan Hi-Flo® 52 Softener Engineer’s Specification Page 6¨ (Meter Initiated systems ONLY)4.4.3 Flow Sensor(s)¨ (1.5” Plastic Turbine Meter)A flow s
Culligan Hi-Flo® 52 Softener Engineer’s Specification Page 7valve controls to admit the correct volume of fresh water to the brine tank in accordance
More
HI-FLO® 52AUTOMATIC WATER SOFTENERSSPECIFICATIONS AND OPERATING DATAMODELS Model 180 Model 300 Model 450 Model 600 Model 750 Model 900Capacity1, grain
Hi-Flo 52MoreCAD File: Soft_HF52_stl.dwg
Hi-Flo 52CAD File: Soft_HF52_frp.dwg
CUSTOMER:AUTOMATIC WATER SOFTENERHI-FLO® 52DATE:1.0 SCOPE1.1 Provide as indicated a vertical pressure type water softener system complete with pressur